LABConnect™

Login
US East Coast: 800-220-3675 | US West Coast: 866-798-1089 | Canada: 888-831-0722

Sewage Screen (M019 / M025 / M114 / M115 / M116 / M129 / M251)

Category Microbiology Laboratory
Test Sewage Screen (M019 / M025 / M114 / M115 / M116 / M129 / M251)
Description Sewage Screen

Sewage Screen (Total Coliform, Fecal Coliform, E. coli, and Fecal Streptococcus)
EMSL Test Code: M025
Bottle Size: Two 250 mL or 1 Liter
Method: SM9222B (M018), SM9222D (M019), SM9230C (M029)
Regulatory Hold Times: 8 hr non-potable, 30 all others (M018), 8 hr non-potable, 24 all others (M019), 8 hr non-potable, 24 all others (M029)

Sewage Screen - Presence/Absence (Total Coliform, E. coli, Enterococci)
EMSL Test Code: M115
Bottle Size: 250 mL
Methods: SM9223B (Colilert) (M017), SM9230D (Enterolert) (M129)
Regulatory Hold Times: 30 hours (M017), 8 hr non-potable, 24 all others (M129)

Sewage Screen - MPN (Total coliform, E. coli, Enterococci)
EMSL Test Code: M116
Bottle Size: 250 mL
Methods: SM9223B (Colilert) (M114), SM9230D (Enterolert) (M251)
Regulatory Hold Times: 30 hours (M014), 8 hr non-potable, 24 all others (M251)


*Water hold times apply only if the sample is for compliance purposes.


Return to View all lab services - S